Needle gauge size tells you how wide a needle is, and the scale runs backwards: a higher gauge number means a thinner needle.
Needle gauge to mm and inches
30 gauge is 0.012 inch (0.3048 mm) wide, listed as 0.30 mm in FDA filings. 31 gauge is 0.010 inch (0.254 mm) wide, listed as 0.25 mm in FDA filings. 31G is thinner than 30G by 0.002 inch (0.0508 mm). A bigger gauge number means a thinner needle.
Outside width of the needle tube. Inches from a US tubing maker's chart; mm is that number × 25.4. Gauges 7 to 34 only.
Paste this code into your page. It shows the insulin syringe size chart with one plain credit link.
Learn
More about this page
A 7 gauge tube is 0.180 inch (4.572 mm) wide. A 34 gauge tube is 0.007 inch (0.1778 mm). Pick a gauge below to see its width, or pick two to compare.
What needle gauge means
Gauge is a number for the outside width, or outer diameter, of the metal tube. It is not a length. The number goes up as the tube gets thinner. A small gauge number means a wide needle, and a big gauge number means a thin one. So 18G is wider than 25G, and 31G is thinner than 30G.
Length is a separate number. For insulin needle lengths, see insulin needle size. Insulin syringes in the insulin syringe sizes chart use 27G to 31G, and pen needles go up to 34G. Standard syringes take many gauges; see syringe sizes. For the subcutaneous needle gauge listed for each use, see the table on the insulin needle size page.
Needle gauge size chart
The chart lists 7 to 34 gauge. Injection needles use the same gauge numbers, so you can read an injection needle's gauge here too. For needle lengths, see insulin needle size. The inch widths come from a US maker of needle tubing. The mm column is that same number times 25.4, which is exact. For 27G to 34G, the last column shows the metric size printed in two FDA filings. One of them states testing to ISO 9626, the needle tubing standard.
| Gauge | Outside width (in) | Same in mm | Metric size in FDA filings |
|---|---|---|---|
| 7G | 0.180 in | 4.572 mm | not listed |
| 8G | 0.165 in | 4.191 mm | not listed |
| 9G | 0.148 in | 3.7592 mm | not listed |
| 10G | 0.134 in | 3.4036 mm | not listed |
| 11G | 0.120 in | 3.048 mm | not listed |
| 12G | 0.109 in | 2.7686 mm | not listed |
| 13G | 0.095 in | 2.413 mm | not listed |
| 14G | 0.083 in | 2.1082 mm | not listed |
| 15G | 0.072 in | 1.8288 mm | not listed |
| 16G | 0.065 in | 1.651 mm | not listed |
| 17G | 0.058 in | 1.4732 mm | not listed |
| 18G | 0.050 in | 1.27 mm | not listed |
| 19G | 0.042 in | 1.0668 mm | not listed |
| 20G | 0.0355 in | 0.9017 mm | not listed |
| 21G | 0.032 in | 0.8128 mm | not listed |
| 22G | 0.028 in | 0.7112 mm | not listed |
| 23G | 0.025 in | 0.635 mm | not listed |
| 24G | 0.022 in | 0.5588 mm | not listed |
| 25G | 0.020 in | 0.508 mm | not listed |
| 26G | 0.018 in | 0.4572 mm | not listed |
| 27G | 0.016 in | 0.4064 mm | 0.40 mm |
| 28G | 0.014 in | 0.3556 mm | 0.36 mm |
| 29G | 0.013 in | 0.3302 mm | 0.33 mm |
| 30G | 0.012 in | 0.3048 mm | 0.30 mm |
| 31G | 0.010 in | 0.254 mm | 0.25 mm |
| 32G | 0.009 in | 0.2286 mm | 0.23 mm |
| 33G | 0.008 in | 0.2032 mm | 0.20 mm |
| 34G | 0.007 in | 0.1778 mm | 0.18 mm |
Why two tables can differ a little
The tubing maker lists widths in inches. The FDA filings list a rounded metric size in mm, such as 0.30 mm for 30G. Each size also has a small allowed range. So two charts can differ in the second or third decimal place.
For example, one filing gives 31G a size of 0.25 mm, with an allowed outside width of 0.254 to 0.267 mm. The inch chart gives 0.010 inch, which is 0.254 mm.
How we checked this chart
We compared the inch chart with the metric sizes in two FDA filings, for every gauge both list. The table below is built by the same code that builds the chart above.
All eight gauges agree within 0.0064 mm. For 32G and 34G, the inch chart is a hair under the filed minimum width, by 0.0004 mm and 0.0002 mm. That is far smaller than anything you could see or measure at home. We show it so you know where the numbers came from.
| Gauge | Inch chart in mm | FDA filing | Difference | Inside the filed min and max? |
|---|---|---|---|---|
| 27G | 0.4064 mm | 0.40 mm | 0.0064 mm | no range filed |
| 28G | 0.3556 mm | 0.36 mm | -0.0044 mm | yes |
| 29G | 0.3302 mm | 0.33 mm | 0.0002 mm | yes |
| 30G | 0.3048 mm | 0.30 mm | 0.0048 mm | yes |
| 31G | 0.254 mm | 0.25 mm | 0.004 mm | yes |
| 32G | 0.2286 mm | 0.23 mm | -0.0014 mm | no, just under the minimum |
| 33G | 0.2032 mm | 0.20 mm | 0.0032 mm | yes |
| 34G | 0.1778 mm | 0.18 mm | -0.0022 mm | no, just under the minimum |
Questions
Is a 16 or 18 gauge needle bigger?
16 gauge is bigger. It is 0.065 inch (1.651 mm) wide, and 18 gauge is 0.050 inch (1.27 mm). A smaller gauge number means a wider needle.
Which needle is finer, 20 or 23 gauge?
23 gauge is finer. It is 0.025 inch (0.635 mm) wide, and 20 gauge is 0.0355 inch (0.9017 mm).
What does needle gauge mean?
Needle gauge is a number for the outside width of the needle tube. A higher number means a thinner needle. It does not tell you the length.
Is a 22 or 25 gauge needle bigger?
22 gauge is bigger. It is 0.028 inch (0.7112 mm) wide, and 25 gauge is 0.020 inch (0.508 mm).
Sources
6 sources with read dates
- Vita Needle Company, Hypodermic Tube Gauge Chart, outside width in inches by gauge, read 2026-10-06
- FDA 510(k) summary K230043, Insulin Pen Needle (2023), Table 1, metric size and outside width range for 28G to 34G, testing to ISO 9626:2016, read 2026-10-06
- FDA 510(k) summary K193273, Insulin Syringe (2021), needle widths for 27G to 32G, read 2026-10-06
- FDA 510(k) summary K190054, BD Insulin Syringe (2019), also states testing to ISO 9626:2016 needle tubing, read 2026-10-06
- NIST Guide for the Use of the International System of Units (SP 811, 2008), DOI 10.6028/NIST.SP.811e2008, inch to centimeter factor 2.54, read 2026-10-06
- NIST, SI Units: Length, 1 inch is exactly 25.4 mm, read 2026-10-06